Abstract
Introduction/Aims
Neuralgic amyotrophy (NA) is a multifocal neuropathy involving the nerves of the upper extremity, limiting functional capability and reducing range of motion. The reachable workspace (RWS) is a computerized three-dimensinal analysis system that evaluates the relative surface area (RSA) of an individual's arm reachability and has shown utility in several neuromuscular disorders. The aims of this study were to examine the ability of the RWS to quantitatively detect limitations in upper extremity active range of motion in patients with NA, and correlate these with other upper extremity functional outcome measures.
Methods
Forty-seven patients with NA and 25 healthy age- and sex-matched controls were measured with the RWS. Study participants’ RSAs were correlated with scores on the Shoulder Rating Questionnaire (SRQ), the Disabilities of Arm Shoulder and Hand (DASH) questionnaire, and upper extremity strength measurements using hand-held dynamometry.
Results
Patients with NA showed significantly lower values in the affected arm for all quadrants (except for the ipsilateral lower quadrant) and total RSA compared with controls (P < 0.001). We found moderate correlations between the reachable workspace, the DASH questionnaire result (r = −0.415), and serratus anterior muscle strength (r = 0.414).
Discussion
RWS is able to detect limitations in active range of motion of the affected arm in patients with NA, and is moderately correlated with upper extremity functional measures. RWS can demonstrate impairment of the affected upper extremity in NA and it has potential as a clinical outcome measure.
Neuralgic amyotrophy (NA) is a multifocal neuropathy involving the nerves of the upper extremity, limiting functional capability and reducing range of motion. The reachable workspace (RWS) is a computerized three-dimensinal analysis system that evaluates the relative surface area (RSA) of an individual's arm reachability and has shown utility in several neuromuscular disorders. The aims of this study were to examine the ability of the RWS to quantitatively detect limitations in upper extremity active range of motion in patients with NA, and correlate these with other upper extremity functional outcome measures.
Methods
Forty-seven patients with NA and 25 healthy age- and sex-matched controls were measured with the RWS. Study participants’ RSAs were correlated with scores on the Shoulder Rating Questionnaire (SRQ), the Disabilities of Arm Shoulder and Hand (DASH) questionnaire, and upper extremity strength measurements using hand-held dynamometry.
Results
Patients with NA showed significantly lower values in the affected arm for all quadrants (except for the ipsilateral lower quadrant) and total RSA compared with controls (P < 0.001). We found moderate correlations between the reachable workspace, the DASH questionnaire result (r = −0.415), and serratus anterior muscle strength (r = 0.414).
Discussion
RWS is able to detect limitations in active range of motion of the affected arm in patients with NA, and is moderately correlated with upper extremity functional measures. RWS can demonstrate impairment of the affected upper extremity in NA and it has potential as a clinical outcome measure.
Original language | English |
---|---|
Pages (from-to) | 282-288 |
Number of pages | 7 |
Journal | Muscle & Nerve |
Volume | 66 |
Issue number | 3 |
DOIs | |
Publication status | Published - Sept 2022 |
Keywords
- activity limitations
- neuralgic amyotrophy
- physical examination
- range of motion
- upperextremity