Quantitative determination of the novel anticancer drug E7070 (indisulam) and its metabolite (1,4-benzenedisulphonamide) in human plasma, urine and faeces by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry.

  • J.H. Beumer
  • , H. Rosing
  • , MJ Hillebrand
  • , LG Nan-Offeringa
  • , K Foley
  • , SM Yule
  • , A.J.R. Heck
  • , J.H.M. Schellens
  • , J.H. Beijnen
  • extern

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

E7070 (indisulam) is a novel anticancer drug currently undergoing clinical investigation. We present a sensitive and specific method for the quantitative determination of E7070 and its metabolite M1 (1,4-benzenedisulphonamide) in human plasma, urine and faeces. The analytes and their tetra-deuterated analogues, which were used as internal standards, were isolated from the biological matrix by solid-phase extraction with OASIS cartridges (0.5 mL plasma or 1 mL urine) and by liquid-liquid extraction with ethyl acetate at pH 5 (1 mL faecal homogenate). The analytes were separated on a C8 reversed-phase chromatographic column and analyzed using electrospray ionization and tandem mass spectrometric detection in the negative ion mode. The validated concentration ranges in plasma were 0.1-20 microg/mL for E7070 and 0.01-2 microg/mL for M1. In urine and faecal homogenate, a concentration range from 0.05-10 microg/mL or microg/g, respectively, was validated for both analytes. Validation of the plasma assay was performed according to the most recent FDA guidelines. The assay fulfilled all generally accepted requirements for linearity (r > 0.99, residuals between -8 and 10%), accuracy (-13.5 to 1.4%) and precision (all less than 11%) in the tested matrices. We investigated recovery, stability (working solutions at -20 degrees C and at room temperature, biological matrices at -20 degrees C, room temperature and after 3 freeze/thaw cycles; final extracts at room temperature) and robustness. All these parameters were found acceptable. This method is suited for mass balance studies or therapeutic drug monitoring, as demonstrated by a case example showing plasma concentrations and cumulative excretion of E7070 and M1 in urine and faeces. Furthermore, we show the presence of E7070 metabolites in patient urine.
Original languageUndefined/Unknown
Pages (from-to)2839-48
Number of pages10
JournalRapid Communications in Mass Spectrometry
Volume18
Issue number23
Publication statusPublished - 2004

Keywords

  • Farmacie/Biofarmaceutische wetenschappen (FARM)
  • Farmacie(FARM)

Cite this