Skip to main navigation Skip to search Skip to main content

On the discrepancy of using annual or hourly emission factors for power generation to estimate CO2 reduction of building retrofitting

  • RISE Research Institutes of Sweden AB
  • University of Gothenburg
  • Center for Research and Technology - Hellas

Research output: Contribution to journal › Article › Academic › peer-review

Abstract

Buildings play a significant role in global carbon emissions, and offer substantial potential for energy savings and emission reduction. This research delves into the Emission Factor Discrepancy (EFD)—the variance in CO2 emission reduction projections obtained by employing either annual or hourly average Emission Factor (EF) for electricity generation. Through two detailed case studies in the Netherlands and incorporating emission data from the Netherlands, Sweden, and France, the study uncovers the potential magnitude and country-specific variability of the EFD. By demonstrating how the energy mix of a country influences the EFD, the research offers valuable insights into the accuracy of emission calculations for different circumstances, particularly in the context of transitioning to renewable energy sources. We have found that countries with energy sources having low load-following capability and low EFs exhibit a large EFD. Whereas, countries with high EFs and large deployment of Photovoltaics (PV) show a notably large EFD on emission reduction related to PV production. This highlights the importance of carefully selecting EFs when evaluating building retrofits in the context of smart city initiatives. This research highlights the need for establishing a uniform framework for calculating carbon emissions associated with retrofitting in buildings in conjunction with the granularity of data and the specific energy mix of a country.

Original languageEnglish
Article number114499
Pages (from-to)1-13
Number of pages13
JournalEnergy and Buildings
Volume319
DOIs
Publication statusPublished - 15 Sept 2024

Bibliographical note

Publisher Copyright:
© 2024 The Authors

Funding

This work is in part financially supported by Netherlands Enterprise Agency (RVO) , projects Inside-Out 1-2-3 (TKITOE1407302, TEUE318005) and the European Commission in the framework of the Horizon 2020 project IRIS (GA No. 774199) . We are thankful to Arno Peekel, Rogier Bos, Paul Das and Joris van den Heiligenberg, for their support within the IRIS project.

FundersFunder number
European Commission
Rijksdienst voor Ondernemend NederlandTKITOE1407302, 1-2-3, TEUE318005
Horizon 2020774199

    UN SDGs

    This output contributes to the following UN Sustainable Development Goals (SDGs)

    1. SDG 7 - Affordable and Clean Energy
      SDG 7 Affordable and Clean Energy
    2. SDG 11 - Sustainable Cities and Communities
      SDG 11 Sustainable Cities and Communities

    Keywords

    • Building retrofitting
    • CO emission reduction
    • Electricity generation
    • Emission factors
    • Environmental impact assessment
    • Load-following capability
    • Residential buildings
    • Smart city project
    • Temporal resolution

    Fingerprint

    Dive into the research topics of 'On the discrepancy of using annual or hourly emission factors for power generation to estimate CO2 reduction of building retrofitting'. Together they form a unique fingerprint.

    Cite this