Skip to main navigation Skip to search Skip to main content

Modeling façade degradation risks on a cubic building: The impact of spatial wetting- and drying patterns on the hygrothermal response

  • Bruno Vanderschelden*
  • , Aytaç Kubilay
  • , Veerle Cnudde
  • , Tim De Kock
  • , Nathan Van Den Bossche
  • *Corresponding author for this work
  • Ghent University
  • University of Antwerp
  • Swiss Federal Institute of Technology Zurich

Research output: Contribution to journal › Article › Academic › peer-review

Abstract

HAM models have proven their value for analyzing moisture-related pathologies by assessing hygrothermal responses to environmental exposure. In this study, a coupling between CFD and HAM is developed to capture spatial wetting and drying effects, which allows to identify façade degradation patterns. Wind-driven rain (WDR) and evaporation significantly influence the hygrothermal performance and durability of façades, particularly in heritage and renovation. In traditional HAM modeling, WDR and convective heat transfer coefficients (CHTC) are often simplified by applying generic, uniform values across the façade. However, this approximation fails to account for the spatial and temporal variations in WDR and neglects the significant variations in CHTC due to the surrounding velocity flow field. These oversimplifications can limit the validity and accuracy of hygrothermal predictions. This study presents a novel approach by externally coupling CFD simulations with HAM modeling to capture the spatial distribution of WDR and CHTC on building façades. Steady Reynolds-averaged Navier-Stokes equations and Eulerian-multiphase simulations are performed to calculate the wind flow and the rain trajectories with turbulent dispersion of raindrops. Using a cubic low-rise building as a case, the coupled model evaluates the effects of wind and rain exposure on façade deterioration, including frost degradation, salt crystallization, and algae growth. Results indicate that conventional approaches tend to underestimate critical rain loads, while drying potential is overestimated. It highlights how spatial variations in WDR and drying influence degradation mechanisms, emphasizing the need for more detailed spatial analyses. This integrated method provides valuable insights into risks posed by moisture exposure and drying dynamics, offering practical applications for targeted renovation strategies and improved preservation of building materials.

Original languageEnglish
Pages (from-to)45-70
Number of pages26
JournalJournal of Building Physics
Volume50
Issue number1
Early online date3 Dec 2025
DOIs
Publication statusPublished - Jul 2026

Bibliographical note

Publisher Copyright:
© The Author(s) 2025

Funding

The authors disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: The research was supported through the Brain 2.0 initiative from Belspo Project no. B2/212/P2/CLIMPACTH.

FundersFunder number
Belgian Federal Science Policy OfficeB2/212/P2/CLIMPACTH

    Keywords

    • CFD-HAM
    • convective drying
    • hygrothermal response
    • surface pathology
    • wind-driven rain

    Fingerprint

    Dive into the research topics of 'Modeling façade degradation risks on a cubic building: The impact of spatial wetting- and drying patterns on the hygrothermal response'. Together they form a unique fingerprint.

    Cite this