TY - JOUR
T1 - Microbiological hazards associated with the use of water in the post-harvest handling and processing operations of fresh and frozen fruits, vegetables and herbs (ffFVH)
T2 - Part 3 (Fresh-whole FVH process water management plan)
AU - EFSA BIOHAZ Panel (EFSA Panel on Biological Hazards)
AU - Allende, Ana
AU - Alvarez-Ordóñez, Avelino
AU - Bortolaia, Valeria
AU - Bover-Cid, Sara
AU - De Cesare, Alessandra
AU - Dohmen, Wietske
AU - Guillier, Laurent
AU - Herman, Lieve
AU - Jacxsens, Liesbeth
AU - Mughini-Gras, Lapo
AU - Nauta, Maarten
AU - Ottoson, Jakob
AU - Peixe, Luisa
AU - Perez-Rodriguez, Fernando
AU - Skandamis, Panagiotis
AU - Suffredini, Elisabetta
AU - Banach, Jen
AU - Zhou, Bin
AU - da Silva Felício, Maria Teresa
AU - Martino, Laura
AU - Messens, Winy
AU - Botteon, Angela
N1 - © 2025 European Food Safety Authority. EFSA Journal published by Wiley‐VCH GmbH on behalf of European Food Safety Authority.
PY - 2025/1
Y1 - 2025/1
N2 - Water used in post-harvest handling and processing operations is an important risk factor for microbiological cross-contamination of fruits, vegetables and herbs (FVH). Industrial data indicated that the fresh-whole FVH sector is characterised by very variable operational cycle duration (between 8 and 900 h), large product volumes (e.g. more than 6000 tonnes) and process water at 2.8-25.0°C. Intervention strategies were based on water disinfection treatments, mostly using chlorine-based disinfectants. Water replenishment was not observed within studied industries. The industrial data, which included 29 scenarios were used to develop a guidance for a water management plan (WMP) for the fresh-whole FVH sector. A WMP aims to maintain the fit-for-purpose microbiological quality of the process water and consists of (a) identification of microbial hazards and hazardous events linked to process water; (b) establishment of the relationship between microbiological and physico-chemical parameters; (c) description of preventive measures; (d) description of intervention measures, including their validation, operational monitoring and verification; and (e) record keeping and trend analysis. A predictive model was used to simulate water management outcomes, highlighting the need for water disinfection treatments to maintain the microbiological quality of the process water and the added value of water replenishment. Relying solely on water replenishment (at realistic feasible rates) does not avoid microbial accumulation in the water. Operational monitoring of the physico-chemical parameters ensures that the disinfection systems are operating effectively. Verification includes microbiological analysis of the process water linked to the operational monitoring outcomes of physico-chemical parameters. Food business operators (FBOps) should set up and validate a tailored WMP to identify physico-chemical parameters, as well as microbial indicators and their threshold levels, as performance standards for maintaining the fit-for-purpose microbiological quality of the process water during post-harvest handling and processing operations.
AB - Water used in post-harvest handling and processing operations is an important risk factor for microbiological cross-contamination of fruits, vegetables and herbs (FVH). Industrial data indicated that the fresh-whole FVH sector is characterised by very variable operational cycle duration (between 8 and 900 h), large product volumes (e.g. more than 6000 tonnes) and process water at 2.8-25.0°C. Intervention strategies were based on water disinfection treatments, mostly using chlorine-based disinfectants. Water replenishment was not observed within studied industries. The industrial data, which included 29 scenarios were used to develop a guidance for a water management plan (WMP) for the fresh-whole FVH sector. A WMP aims to maintain the fit-for-purpose microbiological quality of the process water and consists of (a) identification of microbial hazards and hazardous events linked to process water; (b) establishment of the relationship between microbiological and physico-chemical parameters; (c) description of preventive measures; (d) description of intervention measures, including their validation, operational monitoring and verification; and (e) record keeping and trend analysis. A predictive model was used to simulate water management outcomes, highlighting the need for water disinfection treatments to maintain the microbiological quality of the process water and the added value of water replenishment. Relying solely on water replenishment (at realistic feasible rates) does not avoid microbial accumulation in the water. Operational monitoring of the physico-chemical parameters ensures that the disinfection systems are operating effectively. Verification includes microbiological analysis of the process water linked to the operational monitoring outcomes of physico-chemical parameters. Food business operators (FBOps) should set up and validate a tailored WMP to identify physico-chemical parameters, as well as microbial indicators and their threshold levels, as performance standards for maintaining the fit-for-purpose microbiological quality of the process water during post-harvest handling and processing operations.
KW - fit-for-purpose water
KW - industry
KW - operational monitoring
KW - validation
KW - verification
KW - wash water
KW - washing
KW - water disinfection
KW - water quality
KW - water safety
U2 - 10.2903/j.efsa.2025.9170
DO - 10.2903/j.efsa.2025.9170
M3 - Article
C2 - 39886073
SN - 1831-4732
VL - 23
JO - EFSA Journal
JF - EFSA Journal
IS - 1
M1 - e9170
ER -