In vivo micro particle image velocimetry measurements of blood-plasma in the embryonic avian heart

Peter Vennemann, Kenneth T. Kiger, Ralph Lindken, Bianca C. W. Groenendijk, Sandra Stekelenburg-de Vos, Timo L. M. ten Hagen, Nicolette T. C. Ursem, Rob E. Poelmann, Jerry Westerweel, Beerend P. Hierck

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

The measurement of blood-plasma velocity distributions with spatial and temporal resolution in vivo is inevitable for the determination of shear stress distributions in complex geometries at unsteady flow conditions like in the beating heart. A nonintrusive, whole-field velocity measurement technique is required that is capable of measuring instantaneous flow fields at submillimeter scales in highly unsteady flows. Micro particle image velocimetry (mu PIV) meets these demands, but requires special consideration and methodologies in order to be utilized for in vivo studies in medical and biological research.We adapt mu PIV to measure the blood-plasma velocity in the beating heart of a chicken embryo. In the current work, bio-inert, fluorescent liposomes with a nominal diameter of 400 nm are added to the flow as a tracer. Because of their small dimension and neutral buoyancy the liposomes closely follow the movement of the blood-plasma and allow the determination of the velocity gradient close to the wall. The measurements quantitatively resolve the velocity distribution in the developing ventricle and atrium of the embryo at nine different stages within the cardiac cycle. Up to 400 velocity vectors per measurement give detailed insight into the fluid dynamics of the primitive beating heart. A rapid peristaltic contraction accelerates the flow to peak velocities of 26 mm/s, with the velocity distribution showing a distinct asymmetrical profile in the highly curved section of the outflow tract.In relation to earlier published gene-expression experiments, the results underline the significance of fluid forces for embryonic cardiogenesis. In general, the measurements demonstrate that mu PIV has the potential to develop into a general tool for instationary flow conditions in complex flow geometries encountered in cardiovascular research. (c) 2005 Elsevier Ltd. All rights reserved.
Original languageEnglish
Pages (from-to)1191-1200
Number of pages10
JournalJournal of Biomechanics
Volume39
Issue number7
DOIs
Publication statusPublished - 2006
Externally publishedYes

Keywords

  • Blood flow
  • Cardiac development
  • Flow shear stress
  • Gene expression
  • Imaging

Fingerprint

Dive into the research topics of 'In vivo micro particle image velocimetry measurements of blood-plasma in the embryonic avian heart'. Together they form a unique fingerprint.

Cite this