TY - JOUR
T1 - Importance of highly selective LC-MS/MS analysis for the accurate quantification of tamoxifen and its metabolites: focus on endoxifen and 4-hydroxytamoxifen.
AU - Jager, N.G.
AU - Rosing, H.
AU - Linn, S.C.
AU - Schellens, J.H.M.
AU - Beijnen, J.H.
PY - 2012
Y1 - 2012
N2 - The antiestrogenic effect of tamoxifen is mainly attributable to the active metabolites endoxifen and 4-hydroxytamoxifen. This effect is assumed to be concentration-dependent and therefore quantitative analysis of tamoxifen and metabolites for clinical studies and therapeutic drug monitoring is increasing. We investigated the large discrepancies in reported mean endoxifen and 4-hydroxytamoxifen concentrations. Two published LC-MS/MS methods are used to analyse a set of 75 serum samples from patients treated with tamoxifen. The method from Teunissen et al. (J Chrom B, 879:1677-1685, 2011) separates endoxifen and 4-hydroxytamoxifen from other tamoxifen metabolites with similar masses and fragmentation patterns. The second method, published by Gjerde et al. (J Chrom A, 1082:6-14, 2005) however lacks selectivity, resulting in a factor 2-3 overestimation of the endoxifen and 4-hydroxytamoxifen levels, respectively. We emphasize the use of highly selective LC-MS/MS methods for the quantification of tamoxifen and its metabolites in biological samples.
AB - The antiestrogenic effect of tamoxifen is mainly attributable to the active metabolites endoxifen and 4-hydroxytamoxifen. This effect is assumed to be concentration-dependent and therefore quantitative analysis of tamoxifen and metabolites for clinical studies and therapeutic drug monitoring is increasing. We investigated the large discrepancies in reported mean endoxifen and 4-hydroxytamoxifen concentrations. Two published LC-MS/MS methods are used to analyse a set of 75 serum samples from patients treated with tamoxifen. The method from Teunissen et al. (J Chrom B, 879:1677-1685, 2011) separates endoxifen and 4-hydroxytamoxifen from other tamoxifen metabolites with similar masses and fragmentation patterns. The second method, published by Gjerde et al. (J Chrom A, 1082:6-14, 2005) however lacks selectivity, resulting in a factor 2-3 overestimation of the endoxifen and 4-hydroxytamoxifen levels, respectively. We emphasize the use of highly selective LC-MS/MS methods for the quantification of tamoxifen and its metabolites in biological samples.
M3 - Article
SN - 0167-6806
VL - 133
SP - 793
EP - 798
JO - Breast Cancer Research and Treatment
JF - Breast Cancer Research and Treatment
IS - 2
ER -