T1 - Evaluation of fritless solid-phase extraction coupled on-line with capillary electrophoresis-mass spectrometry for the analysis of opioid peptides in cerebrospinal fluid
AU - Medina-Casanellas, Silvia
AU - Tak, Yvonne H
AU - Benavente, Fernando
AU - Sanz-Nebot, Victoria
AU - Sastre Toraño, Javier
AU - Somsen, Govert W
AU - de Jong, Gerhardus J
N1 - © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
PY - 2014
Y1 - 2014
N2 - Fritless SPE on-line coupled to CE with UV and MS detection (SPE-CE-UV and SPE-CE-MS) was evaluated for the analysis of opioid peptides. A microcartridge of 150 μm id was packed with a C18 sorbent (particle size > 50 μm), which was retained between a short inlet capillary and a separation capillary (50 μm id). Several experimental parameters were optimized by SPE-CE-UV using solutions of dynorphin A (DynA), endomorphin 1 (End1), and methionine-enkephaline (Met). A microcartridge length of 4 mm was selected, sample was loaded for 10 min at 930 mbar and the retained peptides were eluted with 67 nL of an acidic hydro-organic solution. Using SPE-CE-MS, peak area and migration time repeatabilities for the three opioid peptides were 12-27% and 4-5%, respectively. SPE recovery was lower for the less hydrophobic DynA (22%) than for End1 (66%) and Met (78%) and linearity was satisfactory in all cases between 5 and 60 ng/mL. The LODs varied between 0.5 and 1.0 ng/mL which represent an enhancement of two orders of magnitude when compared with CE-MS. Cerebrospinal fluid (CSF) samples spiked with the opioid peptides were analyzed to demonstrate the applicability to biological samples. Peak area and migration time repeatabilities were similar to the standard solutions and the opioid peptides could be detected down to 1.0 ng/mL.
AB - Fritless SPE on-line coupled to CE with UV and MS detection (SPE-CE-UV and SPE-CE-MS) was evaluated for the analysis of opioid peptides. A microcartridge of 150 μm id was packed with a C18 sorbent (particle size > 50 μm), which was retained between a short inlet capillary and a separation capillary (50 μm id). Several experimental parameters were optimized by SPE-CE-UV using solutions of dynorphin A (DynA), endomorphin 1 (End1), and methionine-enkephaline (Met). A microcartridge length of 4 mm was selected, sample was loaded for 10 min at 930 mbar and the retained peptides were eluted with 67 nL of an acidic hydro-organic solution. Using SPE-CE-MS, peak area and migration time repeatabilities for the three opioid peptides were 12-27% and 4-5%, respectively. SPE recovery was lower for the less hydrophobic DynA (22%) than for End1 (66%) and Met (78%) and linearity was satisfactory in all cases between 5 and 60 ng/mL. The LODs varied between 0.5 and 1.0 ng/mL which represent an enhancement of two orders of magnitude when compared with CE-MS. Cerebrospinal fluid (CSF) samples spiked with the opioid peptides were analyzed to demonstrate the applicability to biological samples. Peak area and migration time repeatabilities were similar to the standard solutions and the opioid peptides could be detected down to 1.0 ng/mL.
U2 - 10.1002/elps.201400293
DO - 10.1002/elps.201400293
M3 - Article
C2 - 25074562
SN - 0173-0835
VL - 35
SP - 2996
EP - 3002
JO - Electrophoresis
JF - Electrophoresis
IS - 20
ER -