TY - JOUR
T1 - Erratum: “Open-source quality control routine and multi-year power generation data of 175 PV systems” [J. Renewable Sustainable Energy 14, 043501 (2022)]
AU - Visser, Lennard R.
AU - Elsinga, Boudewijn
AU - AlSkaif, Tarek A.
AU - Sark, Wilfried G. J. H. M. van
N1 - Publisher Copyright:
© 2024 Author(s).
PY - 2024/3
Y1 - 2024/3
N2 - The authors regret that minor typos ended up in Eqs. (7)–(10) of the original article.1 The corrected version of the equations is outlined below in Eqs. (1)–(4), respectively. On a final note, the explanation, results, and code used and published in the original work were correct; therefore, the results and conclusions remain unchanged. The correct formulation of the expression in Eq. (7) is (Formula Presented). where pm is the measured power output of a PV system at time t. SAC presents the inverter capacity of the PV system (see Sec. III A 2 of Ref. 1) and t is a constant, which is set at 1.025. The correct form of the expressions in Eqs. (8)–(10) are (Formula Presented) where pcs presents the simulated power output of a PV system for clear sky conditions, considering the clear sky irradiance. Furthermore, kPV is a threshold value that is set to 1.4 and SDC is the DC capacity of the PV system, which is estimated as described by Sec. IIIA 1 in Ref. 1. Finally, hz is the solar zenith angle.
AB - The authors regret that minor typos ended up in Eqs. (7)–(10) of the original article.1 The corrected version of the equations is outlined below in Eqs. (1)–(4), respectively. On a final note, the explanation, results, and code used and published in the original work were correct; therefore, the results and conclusions remain unchanged. The correct formulation of the expression in Eq. (7) is (Formula Presented). where pm is the measured power output of a PV system at time t. SAC presents the inverter capacity of the PV system (see Sec. III A 2 of Ref. 1) and t is a constant, which is set at 1.025. The correct form of the expressions in Eqs. (8)–(10) are (Formula Presented) where pcs presents the simulated power output of a PV system for clear sky conditions, considering the clear sky irradiance. Furthermore, kPV is a threshold value that is set to 1.4 and SDC is the DC capacity of the PV system, which is estimated as described by Sec. IIIA 1 in Ref. 1. Finally, hz is the solar zenith angle.
UR - http://www.scopus.com/inward/record.url?scp=85188994488&partnerID=8YFLogxK
U2 - 10.1063/5.0203147
DO - 10.1063/5.0203147
M3 - Comment/Letter to the editor
SN - 1941-7012
VL - 16
JO - Journal of Renewable and Sustainable Energy
JF - Journal of Renewable and Sustainable Energy
IS - 2
M1 - 029901
ER -