TY - JOUR
T1 - Comparison of intake and systemic relative effect potencies of dioxin-like compounds in female rats after a single oral dose
AU - Van Ede, Karin I.
AU - Andersson, Patrik L.
AU - Gaisch, Konrad P J
AU - Van Den Berg, Martin
AU - Van Duursen, Majorie B M
PY - 2014/3/1
Y1 - 2014/3/1
N2 - Risk assessment for mixtures of dioxin-like compounds uses the toxic equivalency factor (TEF) approach. Although current WHO-TEFs are mostly based on oral administration, they are commonly used to determine toxicity equivalencies (TEQs) in human blood or tissues. However, the use of "intake" TEFs to calculate systemic TEQs in for example human blood, has never been validated. In this study, intake and systemic relative effect potencies (REPs) for 1,2,3,7,8-pentachlorodibenzo-p-dioxin (PeCDD), 2,3,4,7,8-pentachlorodibenzofuran (4-PeCDF), 3,3′,4,4′,5-pentachlorobiphenyl (PCB-126), 2,3′,4,4′,5-pentachlorobiphenyl (PCB-118) and 2,3,3′,4, 4′,5-hexachlorobiphenyl (PCB-156) were compared in rats. The effect potencies were calculated based on administered dose and liver, adipose or plasma concentrations in female Sprague-Dawley rats 3 days after a single oral dose, relative to 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD). Hepatic ethoxyresorufin-O-deethylase activity and gene expression of Cyp1a1, 1a2, 1b1 and aryl hydrocarbon receptor repressor in liver and peripheral blood lymphocytes were used as endpoints. Results show that plasma-based systemic REPs were generally within a half log range around the intake REPs for all congeners tested, except for 4-PeCDF. Together with our previously reported systemic REPs from a mouse study, these data do not warrant the use of systemic REPs as systemic TEFs for human risk assessment. However, further investigation for plasma-based systemic REPs for 4-PeCDF is desirable.
AB - Risk assessment for mixtures of dioxin-like compounds uses the toxic equivalency factor (TEF) approach. Although current WHO-TEFs are mostly based on oral administration, they are commonly used to determine toxicity equivalencies (TEQs) in human blood or tissues. However, the use of "intake" TEFs to calculate systemic TEQs in for example human blood, has never been validated. In this study, intake and systemic relative effect potencies (REPs) for 1,2,3,7,8-pentachlorodibenzo-p-dioxin (PeCDD), 2,3,4,7,8-pentachlorodibenzofuran (4-PeCDF), 3,3′,4,4′,5-pentachlorobiphenyl (PCB-126), 2,3′,4,4′,5-pentachlorobiphenyl (PCB-118) and 2,3,3′,4, 4′,5-hexachlorobiphenyl (PCB-156) were compared in rats. The effect potencies were calculated based on administered dose and liver, adipose or plasma concentrations in female Sprague-Dawley rats 3 days after a single oral dose, relative to 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD). Hepatic ethoxyresorufin-O-deethylase activity and gene expression of Cyp1a1, 1a2, 1b1 and aryl hydrocarbon receptor repressor in liver and peripheral blood lymphocytes were used as endpoints. Results show that plasma-based systemic REPs were generally within a half log range around the intake REPs for all congeners tested, except for 4-PeCDF. Together with our previously reported systemic REPs from a mouse study, these data do not warrant the use of systemic REPs as systemic TEFs for human risk assessment. However, further investigation for plasma-based systemic REPs for 4-PeCDF is desirable.
KW - Dibenzofurans
KW - Dioxins
KW - PCBs
KW - Systemic REPs
KW - TEF concept
UR - http://www.scopus.com/inward/record.url?scp=84894548658&partnerID=8YFLogxK
U2 - 10.1007/s00204-013-1186-2
DO - 10.1007/s00204-013-1186-2
M3 - Article
AN - SCOPUS:84894548658
SN - 0340-5761
VL - 88
SP - 637
EP - 646
JO - Archives of Toxicology
JF - Archives of Toxicology
IS - 3
ER -