Comparative accuracy evaluation of patient-specific 3D-printed guide and neuronavigation for ventriculoperitoneal shunt in dogs: a dual-phase ex vivo and in vivo study

  • YoungJin Jeon
  • , Cheongwoon Cho
  • , Jaemin Jeong
  • , Björn Meij*
  • , Haebeom Lee*
  • *Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

BACKGROUND: Ventriculoperitoneal shunting (VPS) is an effective treatment for canine hydrocephalus, but complications related to ventricular catheter (VC) misplacement remain a concern. Although neuronavigation improves accuracy, its cost and complexity limit veterinary use. Patient-specific 3D-printed guiding systems (PS-3DGS) offer a potential alternative.

OBJECTIVES: To compare the accuracy and feasibility of PS-3DGS compared to electromagnetic neuronavigation for VC placement in 3D-printed canine cranio-ventricular models (CVMs) and Beagle dogs.

ANIMALS AND STUDY DESIGN: Ten 3D-printed CVMs ( ex vivo study) and five experimental Beagle dogs ( in vivo study).

METHODS: VC placement was performed using PS-3DGS and neuronavigation in CVMs and experimental animals. Accuracy was assessed by the distance from the VC tip to the foramen of Monro (DFM), tip coordinates (X, Y, Z axes), tip placement error, intraventricular insertion length (IIL), and catheter contact with the ventricular wall (VVL). Intraoperative procedural time and anatomical variables, including skull and cranial indices, were also analyzed.

RESULTS: PS-3DGS showed no significant difference in DFM compared to neuronavigation in CVMs and Beagle dogs. PS-3DGS achieved significantly lower VVL and reduced procedural time than neuronavigation in the CVM study ( p = 0.011 and p = 0.039, respectively). In dogs, DFM with PS-3DGS was comparable to both neuronavigation and the ex vivo results. Entry point error correlated negatively with cranial index (r = -0.9, p = 0.037).

CONCLUSION: PS-3DGS provided accuracy comparable to neuronavigation while simplifying the procedure. It represents a viable, cost-effective alternative for canine VPS surgery, potentially enhancing catheter placement and reducing complications.

Original languageEnglish
Article number1665844
Number of pages14
JournalFrontiers in Veterinary Science
Volume12
DOIs
Publication statusPublished - 14 Nov 2025

Bibliographical note

Copyright © 2025 Jeon, Cho, Jeong, Meij and Lee.

Keywords

  • hydrocephalus
  • neuronavigation
  • patient-specific guides
  • ventricular catheter
  • ventriculoperitoneal shunt

Fingerprint

Dive into the research topics of 'Comparative accuracy evaluation of patient-specific 3D-printed guide and neuronavigation for ventriculoperitoneal shunt in dogs: a dual-phase ex vivo and in vivo study'. Together they form a unique fingerprint.

Cite this