Chronic stability of a neuroprosthesis comprising multiple adjacent Utah arrays in monkeys

Xing Chen*, Feng Wang, Roxana Kooijmans, Peter Christiaan Klink, Christian Boehler, Maria Asplund, Pieter Roelf Roelfsema

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Objective. Electrical stimulation of visual cortex via a neuroprosthesis induces the perception of dots of light ('phosphenes'), potentially allowing recognition of simple shapes even after decades of blindness. However, restoration of functional vision requires large numbers of electrodes, and chronic, clinical implantation of intracortical electrodes in the visual cortex has only been achieved using devices of up to 96 channels. We evaluated the efficacy and stability of a 1024-channel neuroprosthesis system in non-human primates (NHPs) over more than 3 years to assess its suitability for long-term vision restoration.

Approach. We implanted 16 microelectrode arrays (Utah arrays) consisting of 8 × 8 electrodes with iridium oxide tips in the primary visual cortex (V1) and visual area 4 (V4) of two sighted macaques. We monitored the animals' health and measured electrode impedances and neuronal signal quality by calculating signal-to-noise ratios of visually driven neuronal activity, peak-to-peak voltages of the waveforms of action potentials, and the number of channels with high-amplitude signals. We delivered cortical microstimulation and determined the minimum current that could be perceived, monitoring the number of channels that successfully yielded phosphenes. We also examined the influence of the implant on a visual task after 2-3 years of implantation and determined the integrity of the brain tissue with a histological analysis 3-3.5 years post-implantation.

Main results. The monkeys remained healthy throughout the implantation period and the device retained its mechanical integrity and electrical conductivity. However, we observed decreasing signal quality with time, declining numbers of phosphene-evoking electrodes, decreases in electrode impedances, and impaired performance on a visual task at visual field locations corresponding to implanted cortical regions. Current thresholds increased with time in one of the two animals. The histological analysis revealed encapsulation of arrays and cortical degeneration. Scanning electron microscopy on one array revealed degradation of IrOxcoating and higher impedances for electrodes with broken tips.

Significance. Long-term implantation of a high-channel-count device in NHP visual cortex was accompanied by deformation of cortical tissue and decreased stimulation efficacy and signal quality over time. We conclude that improvements in device biocompatibility and/or refinement of implantation techniques are needed before future clinical use is feasible.

Original languageEnglish
Article number036039
Pages (from-to)1-20
Number of pages20
JournalJournal of Neural Engineering
Volume20
Issue number3
DOIs
Publication statusPublished - 30 Jun 2023

Bibliographical note

© 2023 The Author(s).
Creative Commons Attribution license.

Funding

This work was supported by NWO (STW Grant Number P15-42 'NESTOR'; ALW Grant Number 823-02-010 and Cross-over Grant Number 17619 'INTENSE'), the European Union (ERC Grant Numbers 339490 'Cortic_al_gorithms' and 101052963 'NUMEROUS,' H2020 Research and Innovation programme Grant Number 899287 'NeuraViper'), the Human Brain Project (Grant Number 650003), and BrainLinks-BrainTools, Cluster of Excellence funded by the German Research Foundation (DFG, EXC 1086), currently funded by the Federal Ministry of Economics, Science and Arts of Baden Württemberg within the sustainability program for projects of the excellence initiative.

FundersFunder number
Nederlandse Organisatie voor Wetenschappelijke Onderzoek (NWO)P15-42 'NESTOR', 823-02-010, 17619 'INTENSE'
European Research Council339490 'Cortic_al_gorithms', 101052963 'NUMEROUS'
???publication-publication-funding-organisation-not-added???H2020 Grant Number 899287 'NeuraViper'
???publication-publication-funding-organisation-not-added???HBP Grant Number 650003
German Research FoundationDFG, EXC 1086

    Keywords

    • Animals
    • Haplorhini
    • Utah
    • Microelectrodes
    • Action Potentials
    • Blindness

    Fingerprint

    Dive into the research topics of 'Chronic stability of a neuroprosthesis comprising multiple adjacent Utah arrays in monkeys'. Together they form a unique fingerprint.

    Cite this