TY - JOUR
T1 - Analytical Validation of a Volumetric Absorptive Microsampling Method for Therapeutic Drug Monitoring of the Oral Targeted Anticancer Agents, Abiraterone, Alectinib, Cabozantinib, Imatinib, Olaparib, and Sunitinib, and Metabolites
AU - Meertens, Marinda
AU - de Vries, Niels
AU - Rosing, Hilde
AU - Steeghs, Neeltje
AU - Beijnen, Jos H.
AU - Huitema, Alwin D. R.
N1 - Publisher Copyright:
Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.
PY - 2024/8
Y1 - 2024/8
N2 - Background:Volumetric Absorptive Microsampling (VAMS) is a useful tool for therapeutic drug monitoring (TDM) of oral targeted anticancer agents. VAMS aims to improve safety and efficacy by enabling at-home blood sample collection by patients. This study aimed to develop and validate an ultra-high performance liquid chromatography-tandem mass spectrometry method for the quantitative determination of abiraterone, alectinib, cabozantinib, imatinib, olaparib, sunitinib, and the metabolites, Δ(4)-abiraterone (D4A), alectinib-M4, imatinib-M1, and N-desethyl sunitinib, in dried whole blood samples using VAMS to support TDM.Methods:After the collection of 10 L of whole blood sample using the VAMS device, the analytes were extracted from the tip using methanol with shaking, evaporated, and reconstituted in acetonitrile:0.1 mol/L ammonium hydroxide in water (1:1, vol/vol). The extracts were then analyzed using ultra-high performance liquid chromatography-tandem mass spectrometry. Validation experiments based on the ICH M10 guideline were carried out, and stability was evaluated under shipping and storage conditions. VAMS specimens were collected in the outpatient clinic to demonstrate the applicability of the assay.Results:The validated range of the method was considered accurate and precise for all analytes. Accordingly, the validation experiments met the relevant requirements, except for cross-analyte interference. Based on the stability data, shipment can be performed at room temperature within 14 days after sample collection and the VAMS specimen can be stored up to 9 months at-20 and-70°C. Samples from 59 patients were collected at the hospital.Conclusions:The developed method could be used to successfully quantify the concentrations of abiraterone, D4A, alectinib, alectinib-M4, cabozantinib, imatinib, imatinib-M1, olaparib, sunitinib, and N-desethyl sunitinib within the validated range using VAMS. Therefore, the method can be used to estimate the dried whole blood-to-plasma ratios for TDM in the clinic.
AB - Background:Volumetric Absorptive Microsampling (VAMS) is a useful tool for therapeutic drug monitoring (TDM) of oral targeted anticancer agents. VAMS aims to improve safety and efficacy by enabling at-home blood sample collection by patients. This study aimed to develop and validate an ultra-high performance liquid chromatography-tandem mass spectrometry method for the quantitative determination of abiraterone, alectinib, cabozantinib, imatinib, olaparib, sunitinib, and the metabolites, Δ(4)-abiraterone (D4A), alectinib-M4, imatinib-M1, and N-desethyl sunitinib, in dried whole blood samples using VAMS to support TDM.Methods:After the collection of 10 L of whole blood sample using the VAMS device, the analytes were extracted from the tip using methanol with shaking, evaporated, and reconstituted in acetonitrile:0.1 mol/L ammonium hydroxide in water (1:1, vol/vol). The extracts were then analyzed using ultra-high performance liquid chromatography-tandem mass spectrometry. Validation experiments based on the ICH M10 guideline were carried out, and stability was evaluated under shipping and storage conditions. VAMS specimens were collected in the outpatient clinic to demonstrate the applicability of the assay.Results:The validated range of the method was considered accurate and precise for all analytes. Accordingly, the validation experiments met the relevant requirements, except for cross-analyte interference. Based on the stability data, shipment can be performed at room temperature within 14 days after sample collection and the VAMS specimen can be stored up to 9 months at-20 and-70°C. Samples from 59 patients were collected at the hospital.Conclusions:The developed method could be used to successfully quantify the concentrations of abiraterone, D4A, alectinib, alectinib-M4, cabozantinib, imatinib, imatinib-M1, olaparib, sunitinib, and N-desethyl sunitinib within the validated range using VAMS. Therefore, the method can be used to estimate the dried whole blood-to-plasma ratios for TDM in the clinic.
KW - Lc-ms/ms
KW - Oral targeted anticancer drugs
KW - Therapeutic drug monitoring
KW - Volumetric absorptive microsampling
UR - https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=d7dz6a2i7wiom976oc9ff2iqvdhv8k5x&SrcAuth=WosAPI&KeyUT=WOS:001266130600020&DestLinkType=FullRecord&DestApp=WOS_CPL
UR - http://www.scopus.com/inward/record.url?scp=85198675165&partnerID=8YFLogxK
U2 - 10.1097/FTD.0000000000001175
DO - 10.1097/FTD.0000000000001175
M3 - Article
C2 - 38321598
SN - 0163-4356
VL - 46
SP - 494
EP - 502
JO - Therapeutic Drug Monitoring
JF - Therapeutic Drug Monitoring
IS - 4
ER -